Three steps to do when mix RV801, RV901 and RV908
Step1: Use 8 or less than 8 connectors on each receiving card;
Step2: Upgrade firmware of RV801 to ok version and the one of RV901 or RV908 to 4F and use LEDStudio12.64 or older to do the setup;
Step3: Choose normal in Card mode option.
Done.
Effects that might happen
After connecting all the cards and doing the intelligent setup, you might see:
There is color, brightness or greyscale difference on LED screen between each area based on receiving card; Some cards are not working correctly (some lines appear)
Solutions:
1.For color/brightness difference: select Brightness for old (on Receiver2 tab)
2.For greyscale difference: change Row blanking time to 1000 or above
3. For appearing lines: adjust Scan clock (between 10 and 16.7)